SPH Series
Hospitality Infrared Heaters
Specifically Designed For Golf Ranges & Hospitality Applications
- Seven input sizes from 40,000 BTU/HR to 125,000 BTU/HR
- Vented and indirect vented operation.
- Emitter Tubes are all calorized steel for higher radiant efficiency and corrosion resistance.
- Emitter tube terminates inside the reflector body and the products of combustion are discharged under the reflector body to increase the return tube temperature and improve overall efficiency.
- No exposed exhauster motors. The blower is enclosed inside the burner box for quieter system operation and less maintenance.
- Two Point Tube Suspension System with external frame brackets to minimize assembly & installation time.
- Features & Applications
- Specifications
- Requirements
- Documents
Features & Applications
- Driving Range
- Hospitality Environments
Push Through System
- Emitter Tubes are all calorized steel for higher radiant efficiency and corrosion resistance.
- Emitter tube terminates inside the reflector body and the products of combustion are discharged under the reflector body to increase the return tube temperature and improve overall efficiency.
- No exposed exhauster motors. The blower is enclosed inside the burner box for quieter system operation and less maintenance.
- Two Point Tube Suspension System with external frame brackets to minimize assembly & installation time.
- Seven input sizes from 40,000 to 125,000
- Vented and indirect vented operation.
- CSA Design Certified
- Year Limited Warranty On Emitter Tube
Wireless Remote Control Kit Available
Specifications
SPH Dimensions
Model | Single Stage | Two Stage | Total Emitter Length | Minimum Mounting Height |
||||
BTU/HR Input | BTU/HR High Input | BTU/HR Low Input | Vented | Unvented | ||||
20 FT | 30 FT | 20 FT | 30 FT | |||||
SPH 40 | 40,000 | 40,000 | 25,000 | ● | ● | ● | 10 FT | |
SPH 50 | 50,000 | 50,000 | 30,000 | ● | ● | ● | ● | 10 FT |
SPH 60 | 60,000 | 60,000 | 40,000 | ● | ● | ● | ● | 11 FT |
SPH 75 | 75,000 | 75,000 | 50,000 | ● | ● | ● | 13 FT | |
SPH 80 | 80,000 | 80,000 | 55,000 | ● | ● | 13 FT | ||
SPH 100 | 100,000 | 100,000 | 65,000 | ● | ● | 14 FT | ||
SPH 125 | 125,000 | 125,000 | 80,000 | ● | 14 FT | |||
Indicate model number based on Btu/hr input (e.g., 100,000 Btu/hr), total emitter length, (e.g., 100 feet) and gas type (e.g., natural gas single stage input). The unit selection for a straight tube would be SPH-100-N5, *MOUNT HEATERS AS HIGH AS POSSIBLE. Minimums are shown for indoor applications as a guideline for human comfort and uniform energy distribution. For outdoor applications heaters can be mounted lower. Consult your Sunstar representative for the particulars of your installation requirements. |
||||||||
Control Suffix | Type of Gas | Control Option Description | ||||||
N5/ L5 | Natural / Propane | Single Stage Gas Valve- Single Stage Input | ||||||
N7 / L7 | Natural / Propane | Two Stage Gas Valve- Modulating Input – High/Low Fire |
Requirements
SPH Clearances to Combustibles
Model | Mounted Horizontally | |||
Sides | Ceiling* | Below | Ends | |
SPH 40, 50 | 22″ | 8″ | 66″ | 15″ |
SPH 60, 75, 80 | 22″ | 8″ | 70″ | 15″ |
SPH 100 | 28″ | 8″ | 80″ | 15″ |
SPH 125 | 28″ | 10″ | 86″ | 20″ |